With which heat pumps is Luqas compatible?

All heat pumps with a Smart Grid contact (2 contacts provided on 90% of all new heat pumps) can be controlled with Luqas. We tested the following:

 

Brand 

Type 

Connection relay 1

Connexion relay 2

Alpha Innotec

SW H3 • SWC(V) H1/H3 • WZS(V) H3 • PWZS(V) H1/H2/H3

IN5

IN6

LWCV • LWDV • LW(A)V • LW(A)HV • LWAV+ • Paros • LWP

IN3

IN4

Atlantic

Alféa Extensa A.I.

EX1 on X11 looped through to L-5 via LQS relay

EX2 on X11 looped through to L-5 via LQS relay

Alféa Excellia A.I.

EX1 on X11 looped through to L-5 via LQS relay

EX2 on X11 looped through to L-5 via LQS relay

Bosch

All heat pumps

I1

I4

Buderus

All heat pumps

I1

I4

Bulex

GeniaAir Tek HA x-7.2

S21

X41/FB + 0(ꓕ)

GeniaAir Mono HA x-6

S21

X41/FB + 0(ꓕ)

GeniaAir Split HA x-5

S21

X41/FB + 0(ꓕ)

CTC

All heat pumps

K25 (Smart A)

K26 (Smart B)

Daikin 

Altherma 2 CB series(1) 

LAN adapter: X1A/1+2

LAN adapter: X1A/3+4

Altherma 3 D-series (1) 

LAN adapter: X1A/1+2

LAN adapter: X1A/3+4

Altherma 3 E-series 

X5M/9+10

X5M/5+6

Ecoforest

EcoAir with hydrokit internal module
All ecoGeo units

SG signal2: DI2 (NO configured)

SG signal1: DI1 (NO configured)

Hitachi

Yutaki, Yutampo and Hisense Hi-Therma models

SG ready Input 1

SG ready Input 2

Itho Daalderop

HP-S

K2

ES

LG

Therma V Air/Water

TB_SG1

TB_SG2

Midea

M Thermal Arctic

SG contact

EVU contact

Swan 2

SG contact

EVU contact

Mitsubishi 

Ecodan C-series generatie R2

TBI.3 IN11

TBI.3 IN12

Ecodan D-series 

TBI.3 IN11

TBI.3 IN12

Ecodan E-series 

TBI.3 IN11

TBI.3 IN12

Nibe 

All heat pumps

Connecting and assigning to AUX contact

Connecting and assigning to AUX contact

Panasonic

All A2W

DI1 via optional print CZ-NSxP (x=4, 5, 6 of 7)

DI2 via optional print CZ-NSxP (x=4, 5, 6 of 7)

Stiebel Eltron

HPG-I (D/C), HMS, WPL IKCS, HSBC 180, HSBC 200 S, HSBC 300 Cool
Necessary: WPM system manager and ISG module

X1.13.3 on Stiebel WPM system manager

X1.13.1 on Stiebel WPM system manager

Thermastage

Thermastage Compact 05-11

EX1

EX2

Thermastage Compact 13-16

EX1

EX2

Thermia 

Atlas 

BM card: D21 (408) or EM3 card D95 (408)

BM card D22 (409) or EM3 card D96 (409)

Calibra 

BM card: D21 (408) or EM3 card D95 (408)

BM card D22 (409) or EM3 card D96 (409)

Mega 

BM card: D21 (408) or EM3 card D95 (408)

BM card D22 (409) or EM3 card D96 (409)

Athena 

BM card: D21 (408) or EM3 card D95 (408)

BM card D22 (409) or EM3 card D96 (409)

Vaillant 

aroTHERM pure /7.2 (uniTOWER /7.2)

S21

X41/FB + 0(ꓕ)

aroTHERM plus /6 (uniTOWER VIH /6 / VWZ MEH 97)  

S21

X41/FB + 0(ꓕ)

aroTHERM /5 

S21

X41/FB + 0(ꓕ)

flexoCOMPACT /4 

S21

X41/FB + 0(ꓕ)

flexoTHERM /4 

S21

X41/FB + 0(ꓕ)

aroTHERM VWL /2

S21

X41/FB + 0(ꓕ)

Viessmann 

All Vitocal heat pumps (since 08/2018).

W01C control: 216.1
One Base control: 143.4

W01C control: 216.4
One Base control: 143.5

Weishaupt

WWP WEM / WWP T300A / WWP WPM

SGR1 – input H1

SGR2 – input H2

LAN adapter module required (version BRP069A61)

This list is not exhaustive. Other Smart Grid-ready heat pumps can be found at https://www.waermepumpe.de/normen-technik/sg-ready-datenbank/.

 

All heat pump boilers with PV contact

 

Brand 

Type 

Connection relay

Atlantic

Explorer V4

Relay on A1 and B2, bridge between A2 and B1.

Calypso VM

Black screw terminal I1.

Calypso Split inverter

Connection 11 & 12.

Ariston

Nuos Plus Wifi

SIG2 (switching with Luqas relay at 230V)

Nuos Split Inverter Wifi

SIG2 (switching with Luqas relay at 230V)

Bosch

Compress 5000DW

‘GND’ and ‘KEIN’

Bulex

MagnaAqua /3 (C)

PV ECO via HP contact (1: off-peak hours, only WP) or PV MAX via HP contact (2: WP hygrostat + resistance)

DC Innova

Aircoheater 2.0

CP contact

Itho Daalderop

WPU

I2 on the control board.

Stiebel Eltron

SHP-A 220 series (from 2018)

X3/1 and X0/1, see the Stiebel Eltron manual for the complete diagram.

SHP-F 300 series (from 2018)

X3/1 and X0/1, see the Stiebel Eltron manual for the complete diagram.

Thermor

Aeromax Premium Version 4

Relay on A1 and B2, bridge between A2 and B1.

Vaillant 

aroSTOR VWL B(M)

PV ECO through HP contact (1: off-peak hours, HP only) or PV MAX through HP contact (2: HP + resistor)

Viessmann

Vitocal 262-A type T2W

FV/PV contact

Vitocal 060-A

Multifunction relay

Wolf

All models

SG/PV contact